MENDOTA GAS DIRECT VENT FIREPLACE with Premium Texture Fiber Logs Combustion System Model DXV-35 DT3 - LX INSTALLATION & OPERATING INSTRUCTIONS
9 GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly effic
10 VENT OPTIONS DISCUSSION This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brands of c
11 GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fi
12 GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Problems such as changes in flame
13 EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 2: Exterior Vent Locations ∨ - Vent Terminal ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF
14 GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Br
15 GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas
16 outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed
17 TOP FLUE VENTING COMPONENTS ITEM DESCRIPTION 1 12" VENT STACK 1 24" VENT STACK 1 36" VENT STACK 1 48" VENT STACK 2 90ºGALVA
18 FLUE VENTING ALLOWANCE CHART NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 19 NOTE: FOR LPG AND HIGH ALTITUDEAPPLICATIONS, SEE PAGE 19. NOTEFig
In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • A CO
19 L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in plac
20 MINIMUM RISE THROUGH-THE-WALL VENTING: The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the firep
21 VENTING COMPONENTS LIST NOTE: ALL PART NUMBERS LISTED ABOVE APPLY TO SIMPSON DURAVENT COMPONENTS ONLY. MENDOTA # DESCRIPTION45-01-00186 7&quo
22 ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. F
23 VERTICAL THROUGH-THE-ROOF VENTING The maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a ru
24 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken.
25 GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Using an 1/8” drill bit, drill through 3 rivets on each side of glass
26 DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS
PLACELOG#1(REARLOG) ONREARSHELFBEHINDREARBURNER.PUSHLOGINTORECESS IN BACK BRICK PANELLOG# 1RECESSINBACKBRICKPANEL.THERECESSSHAPEM
LOG#2(MIDEMBERBED)SITSBETWEENREARANDFRONTBURNER,FLATDOWNONTHESURFAC EOFTHEBURNERAIRBOX.ADJUSTPOSITIONOFFRONTANDREARBURNERSI
2 DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep MINIMUM FRAMING DIMENSIONS: 37-1
PLACELOG#3(LEFTLOG)ONTOPOFTHE RECTANGLEAIRSHUTTERBOXONTHELEFTSIDE.LOG#3HASARECTANGULARNOTCHONITSBOTTOMSIDETHATALLOWS THE L
LOG#4(RIGHTLOG)HASAHOLEFORTHEPINONLOG#2.INSERTPININLOG#2INTOHOLEINLOG#4.LOG#4.SOMEROTATIONALFLEXIBILITYISALLOWEDTOLOG#4
LOG#5(LEFTTOPLOG)SITSONTHELEFTSHOULDEROFLOG#1ANDITSTWOBRANCHESSITONTOPOFLOG#2ANDLOG#3.LOG#5HASAHOLETHATALIGNSWITHTHE
LOG#6(RIGHTTOPLOG)SITSONTOPOFLOG#1USINGTHEPINTHATISONTHERIGHTSIDEOFLOG#1.LOG#6HASAHOLEINITSBACK‐SIDETOMATEWITHTHISP
LOG#7LOG#7RESTONTOPOFTHEFRONTBURNER’SREARVISIBLEEDGEANDONTOPOFLOG#4. THISLOGISDESIGNEDTOHIDETHEPILOTLIGHT.PLACETHISLOGS
PLACELOG#8(LEFTFRONTTWIG)INTHEPOSTIONSHOWNHERE.LOG#8SITSONTOPOFLOG#2ANDRESTSAGAINSTTHEGRATEBAR(2NDFROMLEFT).LOG#8ATTEMPTT
LOG#9LOG# 9LOG#9LOG#9(RIGHTFRONTCHUNK)ISTOBEPLACEDATASEVEREANGLEAGAINSTTHEHORIZONTALGRATEBARANDFLOATINGOVERTHEFRONTBURNERPOR
COMPLETEDLOGSETASSEMBLY36
37 The following Check Off Lists mustINSTALLATION CHECK OFF LIST be completed prior to final operation of the Fireplace, or manufac-turer's wa
38 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace. Failure to follow the instructions may result in property dam-age, b
3 TABLE OF CONTENTS FOR YOUR SAFETY READ BEFORE LIGHTING ...
39 Remote Control Transmitter Functions NOTE: The Wall Receiver will “beep” once every time a Remote Transmitter Key is pressed, signaling that the
40 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE1. Press the ON/OFF button. The transmitter display will show all active i
41 MANUAL BYPASS OF THE REMOTE SYSTEM If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the three
42 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have
43 Backup Batteries The life span of the backup batteries depends on the quality of the batteries used and how long the batteries have been installe
44 BLOWER OPERATION AND WIRING WARNINGDual blowers are provided as standard equipment with this DXV35 DT3 Fireplace. The dual blowers have an air
45 TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (soot) forms on viewing glass. A.
46 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Fireplaces comply with UL Standards for maximum surface t
47 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved serv
48 WIRING SCHEMATICS Note: The DXV35-DT3-LX ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power out
4 INITIALIZING THE REMOTE CONTROL SYSTEM ...
49 NATURAL TO LP GAS CONVERSION INSTRUCTIONS Kit # HA-30-00507 Mendota Model DXV35 DT3 This conversion kit shall be installed by a qualified service
50 Use an Alan WrenchTo loosen and removeNG Pilot Orifice. InstallLP Pilot Orifice, TightenDown.Pull Pilot Hood UPand lift UP off the base.WIRE CLIP
51 10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” mi
52 INSTALLING THE LP PRESSURE REGULATOR WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY BEFORE YOU ATTEMPT T
53 INLET TAP OUTLET TAP LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only ac
54 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER (S) I
55 REPLACEMENT PARTS MENDOTA GAS DXV-35 DT3 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION 65-02-00103 TADPOLE GLASS GASKET (106”) 05-04
56 MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-35 Fireplace: 1. Andover, Bentley Arc
57 HEARTH PAD SURFACE MUST BE FLUSH WITH FIREPLACE BOTTOMIF INSTALLING THE WELLINGTON!!HEARTH PADSURFACEInformation specific to the installation of
58 RATING LABEL REPRESENTATION DXV35 DT3
5 SPECIFICATIONS MODEL DXV-35 DT3 INPUT RATES (Btu/Hr) High Fire - Adjustable to - Low FireNAT. GAS 33,000 10,000 LP GAS
59 THIS PAGE LEFT BLANK INTENTIONALLY
60 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form ver
61 TAPE SHUT ------------------------------------------------------------------------------------------------------------------
62 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA DXV-35-DT3-LX DIRECT VENT FIREPLACE Mendota Division of Johnson Gas Applian
Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division
6 Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common
7 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-tions
8 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Fire
Comentários a estes Manuais